Input
Frequency.................................................65.00 to 75.00 MHz |
 |
Pre-detection
Bandwidth..........................................50kHz Standard
Other Bandwidths available |
 |
Input Level...........................-85 dBm,
minimum; -25 dBm, maximum For full tracking range capability |
 |
Frequency
Tuning.......................................................10 kHz Steps |
 |
Frequency
Adjust........................................Front Panel or Remotely |
 |
AFC.................................................................................+
23 kHz |
 |
Threshold........................................<45
dB-Hz (C/N0) for acquisition |
 |
Input
Impedance.................................................................50 Ohm |
 |
Input
Connector..................................................Type-BNC, Female |
 |
Output
Impedance........................................100 Ohm, single ended |
 |
Output
Connector..............................Terminal plug and BNC
Female |
 |
Tracking
Gradient...............................................0.5 V/dB, Standard |
 |
Tracking
Response..........0 to +10 VDC for a 20dB input level change |
 |
System
Level
Adjust....................................0 to 60 dB,0.5 dB steps |
 |
Frequency
Stability.........................................<1 ppm,
00c to +500c |
 |
Frequency
Reference.............................................10 MHz
(Internal) |
 |
Phase
Noise.......................................>75 dB-Hz, 1kHz
from Carrier |
 |
Alarms............................................................................Unit
Lock |
 |
Alarm
Relay........................................................................Form-C |
 |
External
Power.......................................................................None |
 |
Continuous Digital
Streaming (CDS)......................RS-232 or RS-422 DB9
Interface connector on rear................
(Optional) SEE BELOW * |
 |
Front
Panel Display..........................................Vacuum
Fluorescent |
 |
M
&
C......................RS-232
or RS-422/485 Switchable on rear panel
Ethernet 10/100 Base T (optional) |
 |
M
& C
Connector.......................................................DB-9,
Female
RJ-45 Connector |
* CDS Continuous
Digital Streaming
The streaming option associated with the ASC300-70 series beacon
receiver provides a continuous, two byte, data stream
running at 9600 baud that contains ten bits of signal
strength level indication as well as lock or alarm condition of
the unit. A female DB9,interface connector on the rear of the unit is specifically
dedicated for this option.
For
Sales Quotation Call
or Email:
sales@atlanticsat.com
For
Engineering Questions Call or Email:
engineering@atlanticsat.com
Product
Spec.
Sheet

Back
to Product Page
Beacon Receiver
Data
View Sheet